Bladeren bron

GPIOPWM: Fixed misleading label "duty cycle" to "frequency", and handle decimal frequency values. Tested working with Rpi.GPIO

pull/130/head
bertah 8 jaren geleden
bovenliggende
commit
65833b1249
1 gewijzigde bestanden met toevoegingen van 5 en 5 verwijderingen
  1. +5
    -5
      modules/base_plugins/gpio_actor/__init__.py

+ 5
- 5
modules/base_plugins/gpio_actor/__init__.py Bestand weergeven

@@ -36,10 +36,10 @@ class GPIOSimple(ActorBase):
class GPIOPWM(ActorBase):

gpio = Property.Select("GPIO", options=[0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27], description="GPIO to which the actor is connected")
duty_cylce = Property.Number("Duty Cycle", configurable=True)
frequency = Property.Number("Frequency (Hz)", configurable=True)

p = None
power = 100
power = 100 # duty cycle

def init(self):
GPIO.setup(int(self.gpio), GPIO.OUT)
@@ -50,10 +50,10 @@ class GPIOPWM(ActorBase):
if power is not None:
self.power = int(power)

if self.duty_cylce is None:
duty_cylce = 50
if self.frequency is None:
self.frequency = 0.5 # 2 sec

self.p = GPIO.PWM(int(self.gpio), int(self.duty_cylce))
self.p = GPIO.PWM(int(self.gpio), float(self.frequency))
self.p.start(int(self.power))

def set_power(self, power):


Laden…
Annuleren