mirror of
https://github.com/Manuel83/craftbeerpi3
synced 2026-08-09 18:52:40 +02:00
Improved descriptions for fermenter hysteresis
This commit is contained in:
@@ -6,10 +6,10 @@ from modules.core.props import Property
|
||||
@cbpi.fermentation_controller
|
||||
class Hysteresis(FermenterController):
|
||||
|
||||
heater_offset_min = Property.Number("Heater Offset ON", True, 0, description="Offset as decimal number when the heater is switched on. Should be geather then 'Heater Offset OFF'. For example 2 means the heater will be switched on if the current temperature is 2 degrees above the target temperature")
|
||||
heater_offset_max = Property.Number("Heater Offset OFF", True, 0, description="Offset as decimal number when the heater is switched off. Should be smaller then 'Heater Offset ON'. For example 1 means the heater will be switched off if the current temperature is 1 degrees above the target temperature")
|
||||
cooler_offset_min = Property.Number("Cooler Offset ON", True, 0, description="Offset as decimal number when the cooler is switched on. Should be geather then 'Cooler Offset OFF'. For example 2 means the cooler will be switched on if the current temperature is 2 degrees below the target temperature")
|
||||
cooler_offset_max = Property.Number("Cooler Offset OFF", True, 0, description="Offset as decimal number when the cooler is switched off. Should be less then 'Cooler Offset ON'. For example 1 means the cooler will be switched off if the current temperature is 1 degrees below the target temperature")
|
||||
heater_offset_min = Property.Number("Heater Offset ON", True, 0, description="Offset as decimal number when the heater is switched on. Should be geather then 'Heater Offset OFF'. For example a value of 2 switch on the heater if the current temperature is 2 degrees below the target temperature")
|
||||
heater_offset_max = Property.Number("Heater Offset OFF", True, 0, description="Offset as decimal number when the heater is switched off. Should be smaller then 'Heater Offset ON'. For example a value of 1 switch off the heater if the current temperature is 1 degree below the target temperature")
|
||||
cooler_offset_min = Property.Number("Cooler Offset ON", True, 0, description="Offset as decimal number when the cooler is switched on. Should be geather then 'Cooler Offset OFF'. For example a value of 2 switch on the cooler if the current temperature is 2 degrees above the target temperature")
|
||||
cooler_offset_max = Property.Number("Cooler Offset OFF", True, 0, description="Offset as decimal number when the cooler is switched off. Should be less then 'Cooler Offset ON'. For example a value of 1 switch off the cooler if the current temperature is 1 degree above the target temperature")
|
||||
|
||||
def stop(self):
|
||||
super(FermenterController, self).stop()
|
||||
|
||||
Reference in New Issue
Block a user