diff --git a/modules/base_plugins/fermenter_hysteresis/__init__.py b/modules/base_plugins/fermenter_hysteresis/__init__.py index 7197d29..e5f0d44 100644 --- a/modules/base_plugins/fermenter_hysteresis/__init__.py +++ b/modules/base_plugins/fermenter_hysteresis/__init__.py @@ -6,10 +6,10 @@ from modules.core.props import Property @cbpi.fermentation_controller class Hysteresis(FermenterController): - heater_offset_min = Property.Number("Heater Offset ON", True, 0, description="Offset as decimal number when the heater is switched on. Should be geather then 'Heater Offset OFF'. For example 2 means the heater will be switched on if the current temperature is 2 degrees above the target temperature") - heater_offset_max = Property.Number("Heater Offset OFF", True, 0, description="Offset as decimal number when the heater is switched off. Should be smaller then 'Heater Offset ON'. For example 1 means the heater will be switched off if the current temperature is 1 degrees above the target temperature") - cooler_offset_min = Property.Number("Cooler Offset ON", True, 0, description="Offset as decimal number when the cooler is switched on. Should be geather then 'Cooler Offset OFF'. For example 2 means the cooler will be switched on if the current temperature is 2 degrees below the target temperature") - cooler_offset_max = Property.Number("Cooler Offset OFF", True, 0, description="Offset as decimal number when the cooler is switched off. Should be less then 'Cooler Offset ON'. For example 1 means the cooler will be switched off if the current temperature is 1 degrees below the target temperature") + heater_offset_min = Property.Number("Heater Offset ON", True, 0, description="Offset as decimal number when the heater is switched on. Should be geather then 'Heater Offset OFF'. For example a value of 2 switch on the heater if the current temperature is 2 degrees below the target temperature") + heater_offset_max = Property.Number("Heater Offset OFF", True, 0, description="Offset as decimal number when the heater is switched off. Should be smaller then 'Heater Offset ON'. For example a value of 1 switch off the heater if the current temperature is 1 degree below the target temperature") + cooler_offset_min = Property.Number("Cooler Offset ON", True, 0, description="Offset as decimal number when the cooler is switched on. Should be geather then 'Cooler Offset OFF'. For example a value of 2 switch on the cooler if the current temperature is 2 degrees above the target temperature") + cooler_offset_max = Property.Number("Cooler Offset OFF", True, 0, description="Offset as decimal number when the cooler is switched off. Should be less then 'Cooler Offset ON'. For example a value of 1 switch off the cooler if the current temperature is 1 degree above the target temperature") def stop(self): super(FermenterController, self).stop()