Update __init__.py

This commit is contained in:
Carl Allen
2017-07-11 15:00:35 -05:00
committed by GitHub
parent 2398ce360d
commit 8c0f03c139
@@ -6,10 +6,10 @@ from modules.core.props import Property
@cbpi.fermentation_controller
class Hysteresis(FermenterController):
heater_offset_min = Property.Number("Heater Offset ON", True, 0, description="Offset as decimal number when the heater is switched on. Should be geather then 'Heater Offset OFF'. For example a value of 2 switch on the heater if the current temperature is 2 degrees below the target temperature")
heater_offset_max = Property.Number("Heater Offset OFF", True, 0, description="Offset as decimal number when the heater is switched off. Should be smaller then 'Heater Offset ON'. For example a value of 1 switch off the heater if the current temperature is 1 degree below the target temperature")
cooler_offset_min = Property.Number("Cooler Offset ON", True, 0, description="Offset as decimal number when the cooler is switched on. Should be geather then 'Cooler Offset OFF'. For example a value of 2 switch on the cooler if the current temperature is 2 degrees above the target temperature")
cooler_offset_max = Property.Number("Cooler Offset OFF", True, 0, description="Offset as decimal number when the cooler is switched off. Should be less then 'Cooler Offset ON'. For example a value of 1 switch off the cooler if the current temperature is 1 degree above the target temperature")
heater_offset_min = Property.Number("Heater Offset ON", True, 0, description="Offset as decimal number when the heater is switched on. Should be geather then 'Heater Offset OFF'. For example a value of 2 switches on the heater if the current temperature is 2 degrees below the target temperature")
heater_offset_max = Property.Number("Heater Offset OFF", True, 0, description="Offset as decimal number when the heater is switched off. Should be smaller then 'Heater Offset ON'. For example a value of 1 switches off the heater if the current temperature is 1 degree below the target temperature")
cooler_offset_min = Property.Number("Cooler Offset ON", True, 0, description="Offset as decimal number when the cooler is switched on. Should be geather then 'Cooler Offset OFF'. For example a value of 2 switches on the cooler if the current temperature is 2 degrees above the target temperature")
cooler_offset_max = Property.Number("Cooler Offset OFF", True, 0, description="Offset as decimal number when the cooler is switched off. Should be less then 'Cooler Offset ON'. For example a value of 1 switches off the cooler if the current temperature is 1 degree above the target temperature")
def stop(self):
super(FermenterController, self).stop()